C27 · Pharmaceutical

Pharmaceutical Stainless Steel Plates: 316L/904L Selection and 7 Part Lists

In the Pharmaceutical Industry, we have organized 7 parts using stainless steel: commonly used 316L / 904L, with thickness ranging from 1.5–30 mm.

Clean stainless steel pipes and sanitary membrane valves
Pharmaceutical clean area: Mirror-polished 316L piping, membrane valve, and equipment skids (schematic; actual materials based on media, temperature, and drawings)

7 parts and material list

Part / ComponentRecommended gradeSize / ThicknessSurfaceFailure ModesReference Standards
Reactors/Batch Crystallizers for API316L/904L6–30mm2B/Electropolishing Ra≤0.4μmCorrosion+Cleaning+Intergranular CorrosionASME BPE;GB/T 3280;NB/T 47008
Centrifuges Drum/Filters316LDrum 3–10mmElectropolishing/Acid WashingCentrifugal Stress+Fatigue+FoulingGB/T 3280;JB/T 20139 series
Dryer Interior/Feed Hopper316L1.5–4.0mmElectropolishing Ra≤0.4μmMaterial Adhesion+Cleaning+CorrosionASME BPE;GB/T 3280
Sanitary Diaphragm Valves316L(ASME BPE 1.4435/BN2)DN15–DN100Electropolishing Ra≤0.4μmDead Legs→Microbial Growth; Membrane Aging; 143°C SterilizationASME BPE;3-A;EHEDG;FDA;USP Class VI
Clean Pipes/Fittings/Gauges316L(ASME BPE)1/4″–6″Ra≤0.4μm Electro-polishing; Intergranular Corrosion TestIncomplete Cleaning Leads to Cross-contamination and CorrosionASME BPE;SEMI F20;GB/T 21833
Sterilization Tanks/Injection Water Storage316L3–10mmRa≤0.4μm Electro-polishingCl⁻ Erosion, Welding SCC, Dead Angles BiofilmASME BPE;GB/T 3280;ISPE
CIP Ball Valves/Sampling Valves316LBy InterfaceElectropolish/DegreasingIncomplete Cleaning Leads to Cross-contamination and CorrosionASME BPE;3-A
Table isStandard Configuration.Different parts for the same material may switch from 304 to 316L or 2205 based on usage conditions. Explain clearly, not just specifying grades.

Key Selection Points

  • Most common grades in this industry are 316L (7), 904L (1) —— Numbers in parentheses indicate the number of parts involved, useful for quoting and material preparation.
  • Frequent Cleaning and Disinfection Amplify Crevice and Intergranular Corrosion Risks (4/7 Hits).
  • Welded parts check sensitization and chloride-ion stress-corrosion cracking (3/7 hits).
  • Thickness range 1.5–30 mm: Thin plates are mostly formed pieces (consider bending rebound and deep drawing cracks), thick plates are mostly welded structures (consider heat input and sensitization).

Common issues

Which stainless steel is used most in pharmaceutical manufacturing?
Out of the total 7 parts, 316L appears most frequently (7 hits), followed by 904L (1 hit). Specific to a part still depends on the medium and temperature; for example, both stainless steel countertops could require switching from 304 to 316L if one is exposed to saltwater.
Which parts are prone to issues?
Based on failure descriptions, typical examples include "cleaning pipes/pipe fittings/clamp": weld heat-affected zone intergranular corrosion + rough inner surface → inadequate cleaning; recommended grade 316L (ASME BPE), size 1/4″–6″. For these conditions, it's recommended to specify medium concentration, temperature, and cleaning method in the design phase.
What thickness should be selected?
The listed thickness range is 1.5–30 mm. Thin plates consider forming and surface quality, thick plates consider welding and structural strength; different manufacturers may have varying values for the same part based on your drawings or operating conditions.

Related materials and adjacent industries

Applications7
Thickness1.5–30mm
Added to inquiry list